Built for the
Way You Use It.
A villa elevator is not specified the same way as a hospital lift or a mall escalation system. Sanyo ISquare tailors configuration, capacity, and compliance package to each application — with the same European component quality throughout.
Residential Apartments
India's residential apartment sector operates under increasingly rigorous life safety and RERA compliance requirements. Sanyo ISquare's residential elevator systems are engineered to satisfy EN81-20/50 safety standards — making compliance documentation available to builders, PMCs, and building associations at every stage. Our ARD system ensures no resident is ever trapped during a power cut, while 120-minute fire-rated WITTUR landing doors provide the critical fire compartmentalisation required in multi-storey residential buildings. From 5-floor walk-ups to 20-floor towers, the MRL system saves valuable common area while delivering the quiet, smooth ride residents expect from a quality building.
Technical Features
- 01EN81-20/50 compliance — full certification package provided
- 02ARD (Automatic Rescue Device) — standard on all installations
- 03120-minute fire-rated WITTUR landing doors (EN81-58 / EI 120)
- 04WITTUR modular cassette door system — 30% faster installation
- 05No machine room — 6–10 m² common area saved per building
- 06Quarterly AMC with genuine European spare parts
- 07Emergency lighting and two-way intercom — EN81 standard
Luxury Villas & Bungalows
A villa elevator is not merely a convenience — it is a design element, a safety provision, and a long-term asset. Sanyo ISquare's home lift systems are configured for low pit depths as shallow as 150 mm, making retrofit into existing villa structures feasible without significant civil work. The Sicor gearless machine runs at approximately 55 dB(A) — quieter than a domestic refrigerator — so the lift is felt in the ease of moving between floors, not heard in adjacent bedrooms. Cabin finishes can be specified across stainless steel, mirror panels, back-painted glass, and wood-effect laminates to complement the villa's interior design language. For bungalows with space constraints, compact shaft configurations are available without compromising on safety standard.
Technical Features
- 01Low pit depth — 150 mm option for retrofit installations
- 02Machine room not required — no overhead structural addition
- 03Sicor gearless machine — ~55 dB(A) silent operation
- 04Custom cabin finishes: stainless, mirror, glass, wood-effect
- 05Compact shaft options for space-constrained bungalows
- 06ARD as standard — no passenger entrapment
- 07EN81-20 compliant for 2–6 floor applications
Commercial Offices & IT Parks
Commercial office buildings and IT parks impose high duty-cycle demands on elevator systems — peak morning and evening traffic surges, continuous operation across multiple shifts, and the expectation of near-zero downtime. Sanyo ISquare commercial elevator systems use Ziehl-Abegg VVVF drives with regenerative braking, feeding recovered energy back into the building's electrical system during descent — reducing net elevator energy consumption by up to 30%. Group control with destination dispatch can be integrated to reduce average passenger wait times during peak hours. Access control integration allows lift call permissions to be linked to your building's access management system — restricting floor access by credential rather than physical key.
Technical Features
- 01High duty-cycle rating — built for continuous commercial use
- 02Ziehl-Abegg regenerative VVVF drives — energy recovery to building grid
- 03Group control with destination dispatch — reduces peak wait times
- 04Access control integration — floor-level credential management
- 05Remote monitoring and floor-by-floor diagnostics via WECO/IRIS control
- 06Energy consumption reporting for green building certification
- 0724×7 AMC support available — minimises operational downtime
Hospitals & Healthcare Facilities
Healthcare facilities demand an entirely different set of elevator performance criteria. A patient on a stretcher cannot wait. A surgeon moving between theatres needs a lift that arrives reliably. A critical care unit cannot afford a failed elevator to block floor access. Sanyo ISquare hospital elevator systems are specified to EN81-70 accessibility standards with 1,100 mm wide clear door openings for stretcher and hospital bed transport. The VVVF drive profile is tuned for ultra-smooth start and stop — minimising discomfort for patients during transport. Emergency power supply integration ensures the hospital elevator continues to function from the building's generator during mains failures. Anti-microbial interior options and flush, easy-clean cabin surfaces are available as standard healthcare configurations.
Technical Features
- 01EN81-70 accessible — full wheelchair and stretcher compliance
- 021,100 mm clear door width — stretcher and hospital bed access
- 03Ultra-smooth VVVF ride profile — critical for patient transport
- 04Emergency power supply integration — generator switchover compatible
- 05Priority recall capability — fire service and emergency protocols
- 06Anti-microbial cabin interior surface options
- 07High duty-cycle rating — continuous clinical operations
Retail, Malls & Hospitality
Retail environments and hotels present a unique combination of very high passenger traffic, strong aesthetic expectations, and low tolerance for downtime. A non-functional lift in a mall or hotel lobby is a visible operational failure. Sanyo ISquare high-traffic elevator systems are rated for commercial duty cycles — with door operators tuned for fast opening and closing cycles to minimise dwell time per trip. Cabin aesthetics can be specified to align with a mall or hotel brand: glass cabin options, custom lighting, premium stainless finishes, and digital display integration. The WECO/IRIS control system provides floor-level fault reporting so your facility management team can address minor issues before they escalate to a service call.
Technical Features
- 01High-traffic commercial duty cycle rating
- 02Fast door speed cycles — reduced dwell time per passenger trip
- 03Aesthetic cabin options: glass, stainless, branded finishes
- 04Custom cabin lighting and digital display integration
- 05Floor-level diagnostics — remote fault monitoring via WECO/IRIS
- 06Minimal downtime design — pre-wired modular components
- 07Full AMC support with rapid response SLA available
5
Application Categories
EN81
Compliance Standard
6
European Component Brands
4
States Served in South India
Which Solution Fits Your Project?
Describe your building type, number of floors, and primary use case. Our technical team will recommend the right system configuration and prepare a compliant specification within 48 hours.